Working principle of refrigeration system of refrigerated container
Working principle of refrigerated container refrigeration system
The refrigeration system of refrigerated Containers mainly provides a suitable storage environment for goods that need refrigerated transportation, such as fresh food, medicines, and perishable goods, by controlling the temperature, humidity, and air circulation in the box. So how does it work to maintain the temperature in the box? We will answer this for you in the following article. Generally, the most commonly used method is the compression refrigeration cycle. Its working principle is generally composed of five major processes, which are linked together to complete the refrigeration task.
- Inhalation process
When the compressor of the refrigeration system starts working, it first inhales low-temperature, low-pressure refrigerant gas from the evaporator. In refrigerated containers, commonly used refrigerants include R-134a, etc. Taking the transportation of seafood as an example, the refrigerant temperature in the evaporator may be around -20℃ and the pressure is low. At this time, the compressor is like a "vacuum pump" to draw in the refrigerant gas.
- Compression process
After the inhaled refrigerant gas enters the compressor, the compressor compresses it. Through the mechanical work of the compressor, the pressure and temperature of the refrigerant gas rise rapidly. For example, the pressure of the refrigerant gas may increase from the original low pressure state (such as 0.1-0.3MPa) to about 1-1.5MPa, and the temperature will also increase from the low temperature state to about 70-90℃. This process is like "pressurizing and heating" the gas, so that the refrigerant can better release heat in the subsequent links.
- Condensation process
After leaving the compressor, the high-temperature and high-pressure refrigerant gas enters the condenser. The condenser is usually installed on the outside of the refrigerated container and uses a cooling medium such as external air or seawater to cool the refrigerant. When the refrigerant gas passes through the condenser, it will dissipate heat to the surrounding cooling medium, and its own temperature will gradually decrease, thereby undergoing a phase change from gas to liquid. For example, the refrigerant temperature drops from 70-90℃ to about 30-40℃. In this process, the heat released by the refrigerant is taken away by the external cooling medium.
- Throttling process
After the liquid refrigerant comes out of the condenser, it passes through a throttling device (such as an expansion valve). The function of the throttling device is to cause the pressure and temperature of the liquid refrigerant to drop sharply. After throttling, the pressure of the refrigerant may drop from 1 - 1.5MPa to about 0.1 - 0.3MPa, and the temperature will also drop accordingly, for example, from 30 - 40℃ to about - 20℃. At this time, the refrigerant becomes a low-temperature, low-pressure liquid, ready for the next evaporation heat absorption process.
- Evaporation process
The low-temperature, low-pressure liquid refrigerant enters the evaporator, which is installed inside the refrigerated container. The liquid refrigerant absorbs the heat in the box and vaporizes in the evaporator, thereby reducing the temperature inside the box. For example, when transporting fruit, the refrigerant in the evaporator absorbs the heat emitted by the fruit, and the temperature inside the box can be controlled at about 0 - 5℃, providing a suitable storage temperature for the fruit. The vaporized refrigerant gas is sucked into the compressor again to start a new cycle.
The refrigerated container lowers the temperature inside the box through the work of the refrigeration machine, better preserves and transports goods, and the refrigerant is environmentally friendly and will not cause any damage to the atmospheric environment.